The mission
Inside Mongla's Hailo-8 accelerator (not the K210). The camera runs, topics publish and every health check is green.
What happened
On the vehicle, detections published nothing while the camera and lock ran at 30 Hz, parameters answered and QoS matched.
Detections: none, for ever.
What I believed
Everything said healthy, so the problem is downstream.
- The camera's dead. The camera delivers thirty frames a second. The input is fine.
- Publisher and subscriber disagree on QoS. They match. It was a fair guess: a QoS mismatch had broken this pipeline two days earlier.
What was true
The accelerator device was still held by a previous process. The loader logged FATAL and returned; the detector stayed empty, and the inference loop skipped every frame, silently, forever.
Try it yourself
Loading the diagram. It needs JavaScript; the text around it says the same thing in words.
The fix
A node that can't do its job must exit or shout. Now it does, and the alarm watches the output rate instead of whether the process is alive.
Evidence: 82c4e70
Keep doing
Process up, topics up, zero output is the most dangerous state a robot has.
Do differently
A node that can't do its job must exit or shout. Alarm on output rate, not on liveness.