জলMongla, 7 September 2026

The kill switch that said "clear"

A boolean cannot carry "I don't know". The absence of a signal is not a value.

What happened
Reading the firmware for features nobody was using turned up a whole second board: an ESP32 beside the thruster battery, whose knob makes or breaks propulsion power and reports over a radio link.
What I believed
KILL = 0 on the wire means thruster power is safely off-limits until someone clears it.
What was true
On link loss the firmware deliberately reports the kill as clear, labelled "display-only". It isn't display-only: it's re-emitted on MAVLink. So 0 meant either "power is live" or "nobody is telling us", and a killed hull armed and ran the mission.
Next time
Represent unknown explicitly, refuse to arm on it, and test the link-loss path, not just the switch.
Evidence
2eb06f3